Model
| Stock Ref No
|
| AM LoWatt 290
| 42 64 46
|
| AM LoWatt 400
| 42 64 47
|
| AM LoWatt 290F
| 42 58 09
|
| AM LoWatt 400F
| 42 58 10
|
| AM LoWatt 290FB
| 42 58 11
|
| AM LoWatt 400FB
| 42 58 12
|
Using the Vent-Axia LoWatt range can reduce electrical consumption, thus reducing the overall carbon footprint.
When using heat recovery ventilation, the heating system requirement is reduced thus potentially saving another 500kg of carbon per annum.
Overview
Air Minder is the next generation of wholehouse heat recovery ventilation systems. It will effortlessly remove your home’s polluted air and provide a constant supply of clean filtered air, allowing you and your family to live in an ideal indoor environment. They are installer friendly and fit into many different orientations with their unique ducting turrets rotating to any required angle.
Air Minder is available in two unit sizes, 290 or 400 versions. Air Minder can be installed in lofts, either on the rafters or suspended, or in ceiling voids, large cupboards or basements.
Air Minder combines continuous ventilation with the most advanced heat recovery system available. Sized correctly it will gently ventilate the property at a rate of about half an air change per hour, removing moist air and unpleasant smells from the kitchen, bathrooms and toilets and extracting it to the outside. Fresh filtered air is drawn into living spaces such as bedrooms and living rooms, providing continuous ventilation even when the house is sealed up for the day.
By keeping humidity levels low and introducing warmed fresh filtered air to replace contaminated air, the quality of the internal environment is significantly improved. Continuous
wholehouse ventilation can help reduce relative humidity to below 70% RH, which inhibits the ideal living and breeding conditions of the house dust mite.
For hotter climates, FB models are fitted with a summer by-pass feature which automatically opens to maintain comfort conditions.
Built-in EU3 filters are easily removed from the unit. For less accessible applications or for higher levels of filtration, a separate ceiling mounted EU7 bag filter cassette is available.
Performance
Constant velocity DC motors in the unit ensure that balancing the input and output air volumes is done automatically. Air Minder has a choice of performance settings based on volume of the home and can be boosted to a higher ventilation rate either manually or using remote sensors such as the Vent-Axia Indoor Air Quality Sensor, humidity sensors etc.
Easy Installation
Air Minder is the ultimate in heat recovery brought together in a brilliant ABS and foam composite design. It's simple clip-together modular construction allows Air Minder to be
quickly and easily installed horizontally or vertically. Once installed the user has complete control over the Air Minder system.
Once the lightweight base section is in place, the cell, turrets and top section are simply clipped into position to complete the installation.
The unique circular turrets rotate through 270°, which give the option of connecting straight onto a duct from any angle without creating resistance or reducing airflow.
UK Patent 2 361 992 DE & NL Patent 1 134 510
Air Minder comes complete with a unique LCD control programmer and 15m of signal cable, allowing the controller to be mounted in a convenient central area. There are no batteries and in the event of a power cut the control programme will be retained.
Electrical connection couldn't be simpler, once the cover is removed from the electrical control box, both motor cables are secured by cable clamps and plugged straight onto the PCB. The mains connections are already marked and fast clamp connections are used for the DC controller cable.
Controller
DC Control Programmer - surface controller with LCD status screen. Automatically switches between 3 speeds, slow (night), medium (day) and manual boost.Supplied with each Air Minder unit.
• User programmable or default program
• On/Off/Boost and Sensor mode operation
• Time elapse meter (hours unit has run)
• Auto Summer by-pass (when fitted)
• Auto defrost
• Filter cleaning indicator
• Heating failure cut-out
• Service indicator
|
|
Features
|
| AM LoWatt 290
| AM LoWatt 400
| AM LoWatt 290F
| AM LoWatt 400F
| AM LoWatt 290FB
| AM LoWatt 400FB
|
| Stock Ref No:
| 42 64 46
| 42 64 47
| 42 58 09
| 42 58 10
| 42 58 11
| 42 58 12
|
Perf. Selection 4 Dip Switch selections of 3 speeds
|
|
|
|
|
|
|
| DC Motor Life 000'/hrs
| 70
| 70
| 70
| 70
| 70
| 70
|
| Counterflow Heat Exchanger
|
|
|
|
|
|
|
| Average 90% Efficiency
|
|
|
|
|
|
|
Duct Connection mm dia.
| 150
| 200
| 150
| 200
| 150
| 200
|
| To fit std loft hatch opening
|
|
|
|
|
|
|
| Digital Controller (included)
|
|
|
|
|
|
|
| LCD Information Display
|
|
|
|
|
|
|
Programmable day/week Speed Operation
|
|
|
|
|
|
|
| Day/night speed change - Auto
|
|
|
|
|
|
|
| Boost Feature
|
|
|
|
|
|
|
| Filters EU3
|
|
|
|
|
|
|
| Non-Filter Model
|
|
|
|
|
|
|
| Installation - Horiz.
|
|
|
|
|
|
|
| Installation - Vert (opt)
|
|
|
|
|
|
|
| Condensation Drain Kit
|
|
|
|
|
|
|
| Auto-defrost
|
|
|
|
|
|
|
| Electronic
|
|
|
|
|
|
|
| Constant Flow Motors
|
|
|
|
|
|
|
| Integral Bypass
|
|
|
|
|
|
|
| Electronic Heating Failure Protection
|
|
|
|
|
|
|
| Filter Change Signal
|
|
|
|
|
|
|

Includes
Aspects of Air Minder are patented and the unit is design registered. Available Features may differ by model in your country. Please check with your supplier.
A full range of accessories is available for the ease of installation in either 125/150/200mm diameter which includes flexible ducting, diffusers, joining pieces and
wall termination sets.
Dimensions
In-Line Installation

| Model
| A
| B
| C
| D
| E
| F
| G
| H
| J
| K
| Weight (kg)
|
| AM 290
| 1440
| 700
| 945
| 507
| 150
| 525
| 500
| 150
| 200
| 175
| 28
|
| AM 400
| 1500
| 700
| 945
| 507
| 150
| 605
| 580
| 215
| 160
| 230
| 29
|

Plan Elevation
Side Elevation
Vertical Installation

| Model
| A
| B
| C
| D
| Weight (kg)
|
| Air Minder 290
| 1290
| 1050
| 570
| 720
| 28
|
| Air Minder 400
| 1320
| 1050
| 570
| 750
| 29
|
Vertical Mounting Kit - AM290 - Stock Ref No: 43 62 43
Vertical Mounting Kit - AM375 - Stock Ref No: 43 62 44

AM290 Spigot diameter 150/160mm.
Vent-Axia 150mm insulated Duct fits this spigot diameter.
AM400 Spigot diameter 200mm.
Cleaning & Maintenance
Cleaning intervals depend largely upon the location. Air filters and air supply and extract grilles will generally need to be cleaned at least two or three times a year: and the heat exchanger in the Air Minder unit annually. Fan impellers can be inspected, and cleaned if necessary, when the heat exchanger is cleaned.
• Please refer to the Air Minder Userguide for full details.
Typical Specification
Supply and install Air Minder AM290/AM400 Wholehouse heat recovery unit as manufactured by:
Vent-Axia Clean Air Systems
Fleming Way
Crawley
West Sussex
RH10 9YX
| Performance:
| m³/h
| l/s
| | Max ventilation rate
| AM290
| 290
| 81
| |
| AM400
| 400
| 111
| | N° speed settings
| 12
|
|
Efficiency: The unit should retain up to 90% of the temperature differential of out going air.
Heat exchanger: should be of a multi plate counter flow type constructed out of a polymeric material with ultra sonic welded joints.
UK Patent Application 0310384.3
Motor: should be a Lowatt Energy Saving DC with ball bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with an electronic thermal overload protective device.
Fan: The fan impeller should be of a forward curved centrifugal type, dynamically balanced.
Controls: The unit should be powered via an internal switched mode power supply remotely controlled by a programmable 3-speed night, day and boost switch.
Ducting spigots: The unit should provide 150/200mm Ř (AM290/AM400) spigots for all duct connections.
Filter: Should be a synthetic material tested to minimum of EU3, housed in a plastic bayonet fitted frame.
Condensation: 12.5 mm Ř outlets are provided to suit the orientation of the unit.
Construction: The unit outer case and fan volutes should be moulded from ABS injection moulded plastic.
Mounting:
| Ceiling:
| Horizontal
| | Floor:
| Horizontal only
| | Wall:
| Vertical only (Do NOT Wall Mount Horizontally) - Fitting Kit required
|
Power Consumption:
|
| AM 290
| AM 400
| | Maximum Amps
| 163W
| 286W
| | Minimum Amps
| 14W
| 20W
|
Mains electrical supply: 230VAC 50Hz.
Complies to the following approvals/directives: CE, LVD, EMC.
|