Model
| Stock Ref No
|
| MVDC-MS - Wireless enabled
| 437635
|
| MVDC-MS - Standard
| 437634
|
Overview
With the growing concerns about over ventilating properties, the Multispeed Multivent offers the option of 'Close Control' both in the residential and the commercial sectors. With a DC motor that can be set to ventilate any area up to 444m³, the Multispeed Multivent is the most efficient central extract unit in the UK.
The unit has 7 pre-set speed settings based on typical house sizes, offering performances from 155 to 444m³/h. Within each of the 7 settings are 5 different speeds for various functions such as present, not present, 2 people occupancy, a night time setting and boost.
Once a house size has been selected the controller that comes complete with the unit can be connected to the system. The controller has 5 buttons to select the 5 different speeds.
Installation
The unit can be installed either horizontally or vertically and where the ambient air has a high humidity content condensate drains are provided.
Performance & Power Consumption



|
House Size
| 1
| 2
| 3
| 4
| 5
| 6
| 7
|
|
Watts (W)
| 5.8
| 9.5
| 14.8
| 22.0
| 31.5
| 42.3
| 54.9
|
|
Volume m³/h (FID)
| 155.6
| 206
| 258.9
| 303
| 341.7
| 387.2
| 444.8
|
Dimensions (mm)
Weight: 5.50kg
Sound Levels

|
|
dB(A) @ 3m
|
|
| Casing Breakout
| Duct Inlet 100mm Ø
| Duct Inlet 125mm Ø
|
MVDC-MS High
| 38.8
| 51.7
| 51.5
|
Published dB(A) figures are free field sound levels at 3m with spherical propagation
at a reference level of 2 x 10–5 Pa.The free field sound power level spectra figures
are dB with reference of 10–12 Watts.
Controllers

|
Main Controller
|
|
The main controller has 5 settings and is connected to the Multivent unit by a 3-core mains cable. The settings are: 1 for when the property is occupied, 1 for when the property is unoccupied, 1 for when only two people are present, 1 for night time setting and 1 for a boost setting.
|
• Boost
• Present
• 2 People
• Night time setting
• Not Present
|
= 100% of selected house speed
= 75% of selected house speed
= 50% or 38% (selectable via a jumper/dip switch) of selected house speed
= 40% of the selected house size
= 25% of selected house spee
|
|
Optional Slave Controller
|

Humidstat®
|
The slave controller is wireless and remotely connected to the main controller. Can be used to boost the system by de-pressing the central button. The controller can be set to boost at various intervals between 5mins and 180mins.
|
Typical Specification
Supply and install a Multivent Multispeed Wholehouse Central Extract unit for wholehouse condensation control as manufactured by:
Vent-Axia Clean Air Systems
Fleming Way
Crawley
West Sussex
RH10 9YX
| Performance:
| m³/h
| l/s
| | Max ventilation rate
| 444
| 123.3
| | N° speed per house settings
| 5
|
|
Motor: A brushless LoWatt Energy Saving DC motor should be used with ball race bearings, greased for life. It shall operate up to an ambient temperature of 40°C and have software fault detection.
Fan: Fan: The impeller should be a centrifugal backward curve type, dynamically balanced, mounted directly onto the motor.
Controls: A main controller is supplied as standard providing 5 fixed speeds. There are 7 different house sizes selected at installation via the main controller. Each Wireless controller can provide 1 extra speed from a selection of 10 available as a percentage of the selected house size 10, 20, 30, 40, 50, 60, 70 ,80, 90, 100%).
Up to 4 wireless controllers can be used with one Multispeed Multivent to provide up to 4 additional speeds.
Ducting spigots: Ducting spigots: The unit should have 4-N° 100/125mm Ø extract points and 1 x125mm Ø outlet to atmosphere. (Can be converted to flat ducting).
Filter: not fitted.
Condensation: Two 15mm condensate drain outlets on the side of the unit at both the top and the bottom for different mounting positions.
Construction: The unit should be moulded in ABS plastic.
Sound Levels: Refer to above table for maximum performance.
Mains electrical supply: 230VAC 50Hz.
Complies to the following approvals/directives: LVD, EMC, BEAB and CE.
|